A Test Report from
August 22, 1994
Mr. Kenneth Stowborg,
Quality Control Dept.
ACC Super Petroleum Corporation
P. O. Box 1473
Hawaiian Gardens, CA 90716
Dear Kenneth,
The following are the results of the coating test conducted with the ACC-ET you supplied on August 12, 1991
Equipment:
Power Friction Test System. System is one (1) year old, inclusive
of a 2-1/2 H.P. motor.
Diameter measure system (precision 0.1 micron, tolerance ± 0.1
micron)
Test Procedure:
Setup diameter measure; Contact area is 2 mm linear.
2 oz of ACC was put in the oil reservoir;
Bring pressure on force handle at 30 lbs, 45 lbs, 100 lbs;
Readings were taken at ½ hour, 2 hours and 4 hours.
Results:
Thickness of copper on contact #1
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Sincerely,
Sid S. Mike
Manager